{"product_id":"qbp716886","title":"Jabsco 50890 Diaphragm Waste Pump, 5 GPM, 1-1\/2 in Ports","description":"\u003ch6\u003eOverview\u003c\/h6\u003e\u003cp\u003eThe Jabsco 50890 Waste Pump is a DC diaphragm pump for moving black water from marine holding tanks, available in 12V and 24V versions. It delivers up to 5 US gpm (19 lpm), is self-priming up to 9.5 ft (3 m), and uses 1-1\/2 in (38 mm) ports for common sanitation hose installations.\u003c\/p\u003e\u003cp\u003eThis waste pump is a practical fit for onboard holding tank evacuation where a compact inline pump is needed in a locker, machinery space, or service area. The single diaphragm layout can pass solids, runs without a pre-filter, and can tolerate dry running during normal waste transfer use.\u003c\/p\u003e\u003ch6\u003eKey features\u003c\/h6\u003e\u003cul\u003e\n\u003cli\u003eUp to 5 US gpm (19 lpm) flow for holding tank evacuation and other waste transfer jobs on board.\u003c\/li\u003e\n\u003cli\u003eSelf-priming up to 9.5 ft (3 m), which helps when the pump is mounted away from the tank outlet.\u003c\/li\u003e\n\u003cli\u003e1-1\/2 in (38 mm) port connections match typical non-collapsible marine waste hose.\u003c\/li\u003e\n\u003cli\u003eNo filter is required before the pump, reducing service points in sanitation plumbing.\u003c\/li\u003e\n\u003cli\u003eMulti-position ports and a rotatable pump head give more flexibility in tight installation spaces.\u003c\/li\u003e\n\u003cli\u003eDry running capability helps protect the pump during tank emptying cycles.\u003c\/li\u003e\n\u003cli\u003eCorrosion-resistant parts suit damp marine spaces where sanitation equipment is often installed.\u003c\/li\u003e\n\u003cli\u003eComplies with USCG 183.410, ISO 8846 MARINE ignition protection, and ISO 8849 MARINE bilge pump standard requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch6\u003eVariants\u003c\/h6\u003e\u003cp\u003eThe Jabsco 50890 Waste Pump is offered in two electrical configurations for different onboard DC systems.\u003c\/p\u003e\u003cp\u003eThe voltage, maximum current, and fuse size vary between the two versions. The pump format, 1-1\/2 in (38 mm) ports, self-priming capability, and waste pump application remain consistent across the 50890 range.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e50890-1000: 12V, 8A maximum current, 10A maximum fuse size. This version matches boats with a 12V DC house or sanitation circuit.\u003c\/li\u003e\n\u003cli\u003e50890-1100: 24V, 2.5A maximum current, 5A maximum fuse size. This version matches vessels with a 24V DC electrical system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch6\u003eInstallation and setup\u003c\/h6\u003e\u003cp\u003eThe pump should be plumbed with 1-1\/2 in (38 mm) ID non-collapsible waste hose on both inlet and outlet connections. Suction connections need to be airtight and routed without sharp bends or restrictions, since leaks or collapsed hose can reduce priming and flow.\u003c\/p\u003e\u003cp\u003eThe ports can be rotated to suit the hose route, and the pump head can be repositioned for the available mounting space. When mounted vertically, the motor should sit above the pump head. Rubber grommets are used to reduce vibration transfer into the mounting surface.\u003c\/p\u003e\u003ch6\u003eElectrical and safety notes\u003c\/h6\u003e\u003cp\u003eThe pump motor is for intermittent duty and should not be run continuously for more than 30 minutes. The positive lead should be protected with the correct rated fuse or circuit breaker close to the power source, using the fuse size that matches the selected 12V or 24V version.\u003c\/p\u003e\u003cp\u003eElectrical connections should be made in dry locations whenever possible. In damp or humid areas, sealed connections help limit corrosion, which is especially important on boats used in saltwater.\u003c\/p\u003e\u003ch6\u003eUse on board\u003c\/h6\u003e\u003cp\u003eThis pump suits boats that need a dedicated waste transfer pump for holding tank evacuation without adding a separate pre-filter. It is also a sensible replacement choice when the existing installation already uses 1-1\/2 in sanitation hose and the electrical system matches one of the available voltage options.\u003c\/p\u003e\u003cp\u003eIt is not for petrol, petroleum products, or liquids with a flash point below 100°F (37.8°C). If the discharge thru-hull sits below the waterline, the discharge hose requires a vented loop at least 8 in (20 cm) above the waterline at all angles of heel or trim.\u003c\/p\u003e","brand":"Jabsco","offers":[{"title":"12V \/ 8A \/ 10A","offer_id":52581966217397,"sku":"QBP716886-V1","price":473.99,"currency_code":"USD","in_stock":true},{"title":"24V \/ 2.5A \/ 5A","offer_id":52581966250165,"sku":"QBP716886-V2","price":499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/8171\/1029\/files\/1334447_qbp716886.webp?v=1780201860","url":"https:\/\/www.qualityboatparts.com\/products\/qbp716886","provider":"Quality Boat Parts","version":"1.0","type":"link"}